Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Language
Year range
1.
Braz. j. pharm. sci ; 51(4): 803-810, Oct.-Dec. 2015. tab, graf
Article in English | LILACS | ID: lil-778417

ABSTRACT

abstract A simple stability-indicating RP-HPLC/UV method was validated for determination of beclomethasone dipropionate (BD) in nanocapsule suspensions. Chromatographic conditions consisted of a RP C18column (250 mm x 4.60 mm, 5 µm, 110 Å), using methanol and water (85:15 v/v) as mobile phase at 1.0 mL/min with UV detection at 254 nm. The calibration curve was found to be linear in the concentration range of 5.0-25.0 µg/mL with a correlation coefficient > 0.999. Precision was demonstrated by a relative standard deviation lower than 2.0%. Accuracy was assessed by the recovery test of BD from nanocapsules (98.03% to 100.35%). Specificity showed no interference from the components of nanocapsules or from the degradation products derived from acid, basic and photolytic conditions. In conclusion, the method is suitable to be applied to assay BD in bulk drug and in nanocapsules, and it can be employed to study stability and degradation kinetics.


resumo Um método simples de CLAE-FR/UV indicativo de estabilidade foi validado para a determinação do dipropionato de beclometasona (BD) em suspensões de nanocápsulas. As condições cromatográficas foram: coluna C18 fase reversa (250 mm x 4,60 mm, 5 µm, 110 Å), usando como fase móvel metanol e água (85:15 v/v) a 1,0 mL/min, com detecção UV a 254 nm. A curva de calibração foi linear no intervalo de 5,0-25,0 µg/mL com coeficiente de correlação >0,999. A precisão foi demonstrada por um desvio padrão relativo menor que 2,0%. A exatidão foi avaliada pelo teste de recuperação do BD a partir das nanocápsulas (98,03% a 100,35%). O teste de especificidade não mostrou interferência dos componentes das nanocápsulas e nem dos produtos de degradação derivados de condições ácidas, básicas e fotolíticas. Em conclusão, o método é adequado para ser aplicado na avaliação do BD puro e em nanocápsulas e pode ser empregado para o estudo de estabilidade e degradação cinética.


Subject(s)
Beclomethasone/pharmacokinetics , Chromatography, High Pressure Liquid/methods , Nanocapsules , Nanoparticles , Chromatography, Reverse-Phase
2.
Braz. j. pharm. sci ; 51(3): 561-567, July-Sept. 2015. tab, graf
Article in English | LILACS | ID: lil-766308

ABSTRACT

Hydroxymethylnitrofurazone (NFOH) is a new compound with potential leishmanicidal and trypanocidal activity. Despite its effectiveness, the formulators have to overcome its poor aqueous solubility. Recently, polymeric nano-scale drug delivery systems have proposed for the treatment of neglected diseases. As several studies have confirmed the advantages of such formulations, and this approach provides new analytical challenges, including the need to detect trace amounts of the drug. A suitable method was developed and validated for NFOH determination bound to poly (n-butylcyanoacrylate) (PBCA) nanoparticles. The chromatographic separation was achieved using a C18 column maintained at 25 ºC and an isocratic mobile phase consisting of water and acetonitrile: 80:20 (v/v) at a flow rate of 1.2 mL min-1 and UV-detection at 265 nm. Investigated validation parameters included selectivity, linearity, accuracy, precision and robustness (changes in column temperature, mobile phase composition and flow). The method was specific, the peak of NFOH had no interference with any nanoparticle excipients and no co-elution with main degradation product (nitrofurazone). Linearity was over the range of 0.94 13.11 μg mL-1 (r2=0.999). The method was accurate and precise, recovery of 100.7%, RSD of 0.4%; intra-day and inter-day RSD range 9.98-9.99 μg mL-1 and 0.3% to 0.5%, respectively. Robustness confirmed that method could resist the applied changes. Application of the optimized method revealed an encapsulation efficiency of 64.4% (n=3). Therefore, the method was successfully developed and validated for the determination of the encapsulation efficiency of NFOH-PBCA nanoparticles.


Hidroximetilnitrofural (NFOH) é um novo composto que possui atividade leishmanicida e tripanomicida potencial. Um método apropriado foi desenvolvido e validado para a determinação de NFOH em nanopartículas de poli(n-butil cianoacrilato) (PBCA). A separação cromatográfica foi obtida usando uma coluna C18 (5 µm de tamanho de partícula, 4,6 mm de diâmetro e 150 mm de comprimento), mantida a 25 °C, fase móvel composta de água e acetonitrila 80:20 (v/v), fluxo de 1,2 mL min- 1 e detecção por UV a 265 nm. Investigaram-se os seguintes parâmetros de validação: seletividade, linearidade, exatidão, precisão e robustez (mudanças na temperatura de coluna, proporção da fase móvel e fluxo). O método mostrou-se específico, o pico de NFOH não apresentou interferência dos picos provenientes dos excipientes das nanopartículas e separado do principal produto de degradação (nitrofural). A linearidade foi obtida na faixa de 0,94-13,11 μg mL- 1 (r2=0,999). O método mostrou exatidão (recuperação de 100,7%, DPR de 0,4 %) e precisão (intra-dia e inter-dia, 9,98-9,99 μg mL- 1 e DPR 0,3% a 0,5%, respectivamente). A robustez provou que o método pode resistir às mudanças propostas. Aplicação do método otimizado revelou eficiência de encapsulação de 64,4% (n=3). Portanto, o método foi desenvolvido e validado com sucesso para a determinação da eficiência de encapsulação de nanopartículas de NFOH-PBCA.


Subject(s)
Chromatography, Liquid/classification , Nanoparticles , Nitrofurazone/pharmacokinetics , Enbucrilate , Chromatography, Reverse-Phase
3.
Braz. j. pharm. sci ; 50(1): 213-223, Jan-Mar/2014. tab, graf
Article in English | LILACS | ID: lil-709545

ABSTRACT

A reversed-phase high performance liquid chromatography method was validated for the determination of cefazolin sodium in lyophilized powder for solution for injection to be applied for quality control in pharmaceutical industry. The liquid chromatography method was conducted on a Zorbax Eclipse Plus C18 column (250 x 4.6 mm, 5 μm), maintained at room temperature. The mobile phase consisted of purified water: acetonitrile (60: 40 v/v), adjusted to pH 8 with triethylamine. The flow rate was of 0.5 mL min-1 and effluents were monitored at 270 nm. The retention time for cefazolin sodium was 3.6 min. The method proved to be linear (r2=0.9999) over the concentration range of 30-80 µg mL-1. The selectivity of the method was proven through degradation studies. The method demonstrated satisfactory results for precision, accuracy, limits of detection and quantitation. The robustness of this method was evaluated using the Plackett–Burman fractional factorial experimental design with a matrix of 15 experiments and the statistical treatment proposed by Youden and Steiner. Finally, the proposed method could be also an advantageous option for the analysis of cefazolin sodium, contributing to improve the quality control and to assure the therapeutic efficacy.


Um método cromatográfico em fase reversa foi validado para a determinação de cefazolina sódica em pó liofilizado, a ser aplicado no controle de qualidade em indústrias farmacêuticas. O método por cromatografia líquida foi conduzido em coluna Zorbax Eclipse Plus C18 (250 × 4,6 mm, 5 µm) mantida à temperatura ambiente. A fase móvel consistiu de água purificada: acetonitrila (60 : 40 v/v), com o pH ajustado para 8 com trietilamina. A vazão usada foi de 0,5 mL min-1 e os analitos de interesse foram monitorizados a 270 nm. O tempo de retenção da cefazolina sódica foi de 3,6 min. As áreas dos picos de cefazolina sódica foram lineares na faixa de concentração de 30-80 µg mL-1 (r2 = 0,9999). A seletividade do método foi demonstrada através de estudos de degradação. O método demonstrou resultados satisfatórios para precisão, exatidão, limites de detecção e de quantificação. A robustez do método foi avaliada utilizando o esquema fatorial de Plackett-Burman com uma matriz de 15 experimentos simultâneos, e analisados por tratamento estatístico proposto por Youden e Steiner. Finalmente, o método proposto pode ser também uma opção de êxito para a análise de cefazolina sódica, contribuindo para o controle de qualidade e para garantir a eficácia terapêutica.


Subject(s)
Cefazolin/analysis , Chromatography, High Pressure Liquid/methods , Quality Control , Drug Industry/trends , Freeze Drying/methods
4.
Braz. j. pharm. sci ; 50(4): 895-901, Oct-Dec/2014. tab, graf
Article in English | LILACS | ID: lil-741340

ABSTRACT

A simple, specific, precise, accurate, linear, rapid, economic and validated stability indicating an RP-HPLC method for the simultaneous quantification of cefepime and tazobactam in a dry injection dosage form has been developed. Separation was performed on a 5 µm ACE C18 column with phosphate buffer, pH adjusted to 4.5 with phosphoric acid: methanol (70:30) at a flow rate of 1 mL/min and at a temperature of 25 °C. Regression analysis showed linearity at a detector wavelength of 290 nm in the range of 200-600 μg/mL for cefepime and 25-75 μg/mL for tazobactam. All of the analytes were adequately resolved with acceptable tailing. The percentage content found for cefepime was 99.98% and of tazobactam was 99.49% in the parenteral formulation. The method was validated in terms of linearity, precision, accuracy, specificity, robustness and system suitability according to ICH guidelines. Stress degradation studies were performed on the placebo and drug products, drugs of interest were well resolved from the degradation products. The developed method was effectively applied for the simultaneous quantification of cefepime and tazobactam in a dry injection formulation.


Desenvolveu-se método específico, preciso, exato, linear, rápido e econômico, de validação de estabilidade, indicando o método de CLAE-FR para a quantificação simultânea de cefepima e tazobactam na forma de dosagem injetável seca. A separação foi realizada em coluna C18 de ACE 5 mM com tampão fosfato, pH ajustado para 4,5 com ácido fosfórico:metanol (70:30), em fluxo de 1 mL/min e temperatura de 25 °C. A análise de regressão mostrou linearidade no detector de comprimento de onda de 290 nm, na faixa de 200-600 μg/mL, para cefepima, e 25-75 μg/mL, para tazobactam. Todos os analitos foram, adequadamente, resolvidos com cauda aceitável. O teor percentual encontrado na formulação parenteral foi de 99,98%, para cefepima, e de 99,49%, para o tazobactam. O método foi validado em termos de linearidade, precisão, exatidão, especificidade, robustez e adequação do sistema de acordo com as diretrizes ICH. Estudos de degradação por estresse foram realizados no grupo placebo e nos medicamentos e os fármacos de interesse foram bem resolvidos a partir dos produtos de degradação. O método desenvolvido foi efetivamente aplicado para quantificação simultânea de cefepima e tazobactam na formulação injetável seca.


Subject(s)
Metabolism , Chromatography, High Pressure Liquid/methods , Chemistry, Pharmaceutical/classification , Dosage/analysis
5.
Braz. j. pharm. sci ; 50(4): 793-797, Oct-Dec/2014. tab, graf
Article in English | LILACS | ID: lil-741342

ABSTRACT

A reverse phase HPLC method is described for the determination of 6-mercaptopurine in bulk and tablets. Chromatography was carried on a C18 column using a mixture of acetonitrile and 0.05 mol/L sodium acetate buffer (10:90 v/v) as the mobile phase at a flow rate of 1 mL/min-1 with detection at 324 nm. The retention time of the drug was 3.25 min. The detector response was linear in the concentration of 0.01-5 μg/mL. The limit of detection and limit of quantification were 17 and 52 ng/mL respectively. The method was validated by determining its sensitivity, linearity, accuracy and precision. The proposed method is simple, economical, fast, accurate and precise and hence can be applied for routine quality control of mercaptopurine in bulk and tablets.


Descreve-se método de CLAE em fase reversa para a determinação de mercaptopurina a granel e em comprimidos. A cromatografia foi realizada em coluna C18, utilizando mistura de acetonitrila em tampão acetato de sódio 0,05 mol/L (10:90 v/v) como fase móvel, com fluxo de 1 mL/min e detecção a 324 nm. O tempo de retenção do fármaco foi de 3,25 min. A resposta do detector foi linear na concentração de 0,01-5 μg/mL. O limite de detecção e o limite de quantificação foram de 17e 52 ng/mL, respectivamente. O método foi validado pela determinação de sua sensibilidade, linearidade, acurácia e precisão. O método proposto é simples, econômico, rápido, acurado e preciso e, então, pode ser aplicado para controle de qualidade de rotina da mercaptopurina em batelada e em comprimidos.


Subject(s)
Chemistry, Pharmaceutical/classification , Chromatography, High Pressure Liquid/methods , Mercaptopurine/analysis , Quality Control , Chromatography, Reverse-Phase
SELECTION OF CITATIONS
SEARCH DETAIL